Quality assurance from construction through to ongoing use
Industrial buildings and data centers place exceptionally high demands on environmental control. Moisture penetration into building structures, poor airtightness, or dust accumulating in rooms can cause equipment failure, shorten the building’s service life, or, in the worst case, halt production.
Vertia’s experts provide support for the project throughout its entire lifecycle. During the construction and commissioning phases, we verify the condition of the structures: concrete curing, suitability for coating, and structural integrity. During the operational phase, we keep the conditions of the facilities under control through continuous monitoring and early alerts. The same partner supports the project from the construction site all the way to production use.
We are accustomed to working on projects with tight deadlines and zero tolerance for errors. We have the tools, methods, and experience. We can be on site at a moment’s notice if needed.
Our Customer Promise:
We act quickly and flexibly – We’ll be there whenever you need us
We make things easy – We will ensure that the measurements are taken on time
We don't just settle for measuring – We do everything we can to ensure that your project is completed to a high standard and on schedule
Vertia's Services for Industry and Data Centers
Do you need measurements for quality assurance, continuous environmental monitoring for critical facilities, or help identifying issues? We provide expert services for every stage of your project—conveniently, reliably, and with a deep understanding of the real needs of demanding environments.
Thermal imaging
Find problems before they find you
Thermal imaging reveals moisture damage, heat loss in structures, and hot spots in electrical and HVAC systems. In data centers, thermal imaging is also an effective tool for inspecting power supplies and the condition of equipment rooms.
Learn more about thermal imaging
Air tightness measurement
Air tightness is the foundation of energy efficiency and climate control
Air tightness testing identifies leaks in structures that reduce energy efficiency, expose structures to moisture, and interfere with ventilation. In critical areas, air tightness is directly linked to cleanliness and pressure control.
Moisture Measurement and Mapping
Control moisture — protect structures and equipment
Excessive moisture in concrete or structures can damage sensitive equipment and cause mold damage. Through testing, we ensure that structures are ready for coating or commissioning, and we identify any problem areas.
Learn more about moisture measurement
Environmental Monitoring
Continuous information, proactive action
IoT-based environmental monitoring keeps you informed about temperature, humidity, and pressure differentials in your facilities in real time. Alerts enable you to take action before any anomalies cause damage, and the collected data supports your auditing and compliance needs.
Learn more about environmental monitoring
Tracer test
Determine the exact locations of the leaks
Tracer testing accurately locates air and gas leaks in structures. This method is particularly suitable for spaces that require a high cleanliness class or precise pressurization.
Learn more about the tracer test
Differential pressure measurement
Controlled pressure — controlled environment
Pressure differential measurement ensures that rooms operate at the designed positive or negative pressure levels. This is critical for ensuring the proper functioning of air handling systems in cleanrooms, classrooms, laboratories, and data centers.
Learn more about differential pressure measurement
Sewer and Chimney Inspection
See beyond what the eye can see
Internal pipe inspections reveal blockages, damage, and leaks without the need to open up structures. In an industrial setting, you can anticipate maintenance needs and avoid costly production downtime.
Learn more about sewer and drain line inspections
Dust measurement using a particle counter
Ensuring Clean Air — Making the Invisible Threat Visible
Measurements taken with a particle counter accurately determine the concentration and size distribution of airborne particles in real time. In data centers and the electronics industry, even small concentrations of particles can damage sensitive components. In cleanrooms and class rooms, measurement is often a prerequisite for compliance with standards (e.g., ISO 14644). We provide a clear report on the results for the particle size fractions required by the desired cleanroom classification.
Learn more about dust measurement
Continuous monitoring of conditions on the BuildStat platform

BuildStat consolidates environmental data from critical spaces into a single view—both on desktop and mobile. The platform monitors temperature, humidity, pressure differentials, and particle concentrations in real time, sends automatic alerts for deviations, and records everything as an auditable history.
BuildStat integrates with existing IoT sensors as well as building automation and DCIM systems, so it complements your current monitoring rather than replacing it. You can see the status of your facility at a glance and respond to anomalies before they affect operations.
Why Vertia?
✔ Over 40 surveyors at your service — resources for urgent projects as well
✔ Over 20,000 measured locations — extensive experience in demanding environments
✔ Quick response — available on short notice
✔ Clear reporting — documentation that meets the requirements of authorities, auditors, and partners
✔ Independent expert — We don't sell equipment, just objective information
We're here to help you!